Every penetration you seal and every cavity barrier you fix is part of a building’s fire strategy — and clients now want proof of competence. This NVQ provides it. It costs £750 fixed with no VAT, typically takes 4–8 weeks with assessment carried out remotely or on site from your normal work — no exams, no classroom, and leads to the Blue Skilled Worker card.
Qualification Overview
Passive fire protection keeps fire and smoke inside the compartment where it starts. Fire stopping around services, cavity barriers, fire resisting partitions and coatings on steel all buy time for people to escape. Main contractors and building owners increasingly ask installers to show a recognised qualification. This NVQ is that qualification, evidenced from the installations you already carry out.
A CTG assessor gathers evidence from your live work. That includes photos of penetrations before and after sealing, labels and records for installed systems, and witness statements from your supervisor. A professional discussion covers manufacturers’ instructions, tested details, compartmentation and what to do when site conditions do not match the specification. No exams, no classroom, and assessor visits are included as standard.
You achieve the GQA Level 2 NVQ Diploma in Associated Industrial Services Occupations (Construction) – Passive Fire Protection, qualification code 610/0116/X — the typical qualification route to the Blue Skilled Worker CSCS card.
Qualification Structure
Key information
| Full title | GQA Level 2 NVQ Diploma in Associated Industrial Services Occupations (Construction) – Passive Fire Protection |
| Qualification code | 610/0116/X |
| Pathway group | Passive fire protection — fire stopping, cavity barriers, fire resisting walls, ceilings, ductwork, coatings and doorsets |
| Level | 2 |
| Awarding body | GQA |
| Price | £750 — fixed, no VAT |
| Typical completion | 4–8 weeks |
| Assessment | On-site evidence — no exams, no classroom |
| Typical CSCS route | Blue Skilled Worker |
What the qualification covers
Every candidate completes three mandatory units on health and safety, productive working practices and moving and storing resources. You then complete at least two optional units, worth at least 102 credits, chosen from the passive fire protection work you actually do.
The optional units cover fire stopping and penetration seals, cavity barriers, fire resisting walls, ceilings and ductwork. Others cover dry cladding to steel, reactive and non-reactive coatings, and fire resisting timber doorsets. The qualification totals 112 credits.
Who this NVQ is for
Fire stopping operatives and passive fire protection installers working for specialist contractors, dry lining firms and M&E subcontractors. You should already install systems with minimal supervision. Typical evidence: sealing service penetrations with batts, mastics, collars and wraps; fixing cavity barriers; building fire resisting partitions and ceilings; applying intumescent coatings; and completing installation records and labels.
Entry requirements
No formal entry qualifications. You must currently install passive fire protection on live projects where we can gather evidence. Manufacturer product training is useful, but the NVQ assesses the competence you show on site.
CSCS card route
This Level 2 NVQ is the typical qualification for the Blue Skilled Worker CSCS card under the occupation Passive Fire Protection, together with the CITB Operatives Health, Safety & Environment test. CSCS issues the card, not CTG. See our CSCS cards guide.
Units — mandatory and optional
You achieve the GQA Level 2 NVQ Diploma in Associated Industrial Services Occupations (Construction) – Passive Fire Protection, qualification code 610/0116/X, through three mandatory units plus at least two optional units worth 102 credits or more, drawn from the official GQA specification. Your assessor maps your normal work to these units at enrolment.
Mandatory units (all candidates)
- Conforming to General Health, Safety and Welfare in the Workplace
- Moving, Handling and Storing Resources in the Workplace
- Conforming to Productive Working Practices in the Workplace
Optional units (minimum of two units, 102 credits)
- Installing fire stopping and penetration seals in the workplace
- Installing flexible (non-mechanical) cavity barriers in the workplace
- Erecting fire resisting walls and wall linings in the workplace
- Erecting fire resisting ceiling systems in the workplace
- Installing fire resisting ductwork systems in the workplace
- Installing dry cladding to protect structural steel in the workplace
- Applying thin film reactive coatings in the workplace
- Applying non-reactive spray coatings in the workplace
- Installing fire resisting timber door assemblies and door-sets in the workplace
Most fire stopping operatives combine penetration seals with cavity barriers or fire resisting walls. Tell us your scope at enrolment and we will register the right combination.
Frequently asked questions
How long does the Passive Fire Protection NVQ take?
Typically 4–8 weeks. It is a large qualification, so the timescale depends on how much of your optional unit work is on site at once.
I only do fire stopping — can I still complete it?
You need at least two optional units. Fire stopping usually pairs well with cavity barriers or fire resisting walls, which many operatives already install.
Does work in occupied buildings or on remedial projects count?
Yes. Remedial fire stopping in hospitals, schools and residential blocks is strong evidence, provided the installations follow tested details.
Can our whole fire stopping team enrol together?
Yes. Teams often qualify together, and we plan visits around your programme so several operatives are assessed on one trip.
Rated by the people we qualify
Live Google reviews from CTG candidates and employers across the UK. Read all 52 reviews.
Entry requirements
You are already doing the work day to day, as an employee or self-employed. There are no entry qualifications and no exams — you are assessed on the job you already do.
To start Level 2 qualification you need:
- A relevant job to be assessed in. This is a competence qualification, so you must have access to real work of the right type while you are registered. No workplace, no evidence.
- Proof of identity — a passport, driving licence or similar, as the awarding body requires.
- A National Insurance number, so we can obtain your Unique Learner Number.
- Enough English to explain your work to your assessor and to talk through your evidence.
- A device with a camera — a phone is fine. Evidence is photos and short videos of your own work, uploaded to your e-portfolio.
You do not need: any prior qualification, any classroom attendance, or to sit an exam. Assessment is entirely in your workplace via a remote e-portfolio, nationwide.
Tell us about any support need, disability or learning difficulty when you enrol and we will arrange reasonable adjustments — it does not affect whether you can take the qualification.
The awarding body sets the final entry criteria for each qualification. If you are not sure whether your current role gives you the right evidence, ask us before you book — we would rather tell you honestly than register you for something you cannot complete.
What card does this NVQ lead to?
Leads to the Blue CSCS Skilled Worker card
On completion you can apply for the Blue CSCS Skilled Worker card, proving competence as a passive fire protection installer.
Your NVQ pathway
- Level 2 Skilled
- Level 3 Advanced
- Level 4 Supervisor
- Level 5 Senior Supervisor
- Level 6 Manager
Your current qualification is highlighted. Progress up the pathway as your career develops.
How the e-portfolio assessment works
- Enrol and be assigned a dedicated occupational assessor.
- Gather workplace evidence — photos, videos, witness statements — via our online portal.
- Complete a professional discussion and observations against the 610/0116/X standards.
- Certification, then apply to CSCS for your card.